I am working on a split system. The contactor, cap, breaker, sub panel, all checks out good. I have no indicator lights, that indicates a power problem. How do I check the circuit board? or any recommendations
?
|
|
|
|
|
|
#2 |
|
Junior Member
Trade: furnace and ac technician
Join Date: Apr 2011
Location: washington state
Posts: 10
|
Re: lennox circuit board
did you verify power at the unit? if the power is to unit and you have no indicator lights, i would check xformer next. if that is suppying 24 volts to board, then the on board fuse or board must be bad
|
|
|
|
|
|
#3 |
|
Junior Member
Trade: HVAC Tech
Join Date: Aug 2009
Posts: 9
|
Re: lennox circuit board
What are you working on? M/N Looks like A/C or H/P. Do you have 24V?
|
|
|
|
|
|
#4 |
|
Member
Trade: residential and commercial
Join Date: Jun 2011
Posts: 44
|
Re: lennox circuit board
do you have proper line voltage did you look at the back of the circuit board for burn marks?
|
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| lennox | wayne1178 | General HVAC Discussion | 0 | 05-25-2011 12:09 AM |
| Lennox CB29M blows 25A fuses | Racer_Joe | Commercial HVAC Forum | 8 | 07-13-2010 06:58 PM |
| Trouble with a Lennox - Primary Limit Open Code | premis | Residential HVAC Forum | 7 | 03-21-2010 07:33 PM |
| Lennox HSI series: model number illegible | hvaclover | Residential HVAC Forum | 3 | 06-25-2009 05:11 PM |
| defrost board started a fire | david c h | General HVAC Discussion | 4 | 06-17-2009 11:53 PM |
| Go to Page... |