Duct static pressure question


I'm not a duct expert (my primary field is indoor air quality) so here goes...

3 ton Carrier Infinity packaged unit model 50XT going into existing duct system with 10 x 20 main ducts. The static pressure is 0.1 in the supply and 0.42 inches in the return, so 0.52 is the total static pressure measured in the ducts about 6 inches form the unit flanges. (The return has two right angle bends which are rectangular turns with a pinch down to 8 X 18 where the ducts are mated-the original installer just cut a hole an inch less than the size of the duct and didn't seem to care (or know) that he was creating a turbulence inducing "pinching orifice"!).

Carriers product info shows the same airflow from 0.1 to 1.0 total static pressure. So should I worry about this? Even though its ugly it seems to be within the operating specs, at least roughly in the middle of their chart.

I can desribe the return as follows: 25x25 filter mounted vertically on a 10 x20 that drops down 4 feet then mates into a horizontal 10 x 20 (with the 10 inch side mounted into the 20 inch side!) that goes just a few inches and then makes a 90 degree turn into the main return duct also 10 x 20 and runs horizontally straight into the unit's return flange.

Can anything be done to improve the flow short of ripping it out? (Soffits etc are involved) Or is it OK as is?


Last edited by engineer; 08-21-2011 at 02:14 PM.
engineer is offline  
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. HVACSite.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Micron meter question tinman Residential HVAC Forum 10 10-25-2011 03:21 PM
Question on BTUH Ratings swtga Residential HVAC Forum 1 04-15-2011 10:53 AM
green slime question?? snooked321 Residential HVAC Forum 8 03-14-2011 04:44 PM
wrightsoft question Hoozdis Residential HVAC Forum 0 03-01-2011 06:46 PM
VS blower static beenthere General HVAC Discussion 4 06-25-2009 12:01 AM

Join Now... It's Fast and FREE!

Privacy Badge
I am a professional contractor
I am a DIY Homeowner
HVACSite.com is for
PROFESSIONAL HVAC CONTRACTORS ONLY!

At HVACSite.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?


SEO by vBSEO 3.6.0